Cerradura con pestillo motorizada para sistemas de marcos tubulares
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Installation instructions
B-1893x | B-1993x
Motor-driven shoot-bolt lock for narrow stile systems
ISR 15
48
y
y
If no errors occur during the test run, the red LED at the controller lights up and the signal
contact 1 "Locked by motor" closes.
Fig.7: Test run successful
If an error occurs, the controller outputs corresponding blink codes (see point 5.1).
Eliminate the displayed error and repeat the test run (see point 6.5).
y
y
Now remove the copper-coloured transport securing devices from the latch and deadbolt trig-
gers.
y
y
Then remove the service plug.
Keep the service plug and do not throw it away!
The service plug is required to activate the programming mode (see point 6).
Fig.8: Removing the service plug
y
y
The motor-driven shoot-bolt lock can now be used.