Anleitung BM 190-12 sprachig
11. Troubleshooting
Caution!
For your own safety, always set the switch to
OFF and pull the power plug out of the socket-
outlet before you carry out any maintenance
work.
Fault:
Blades break
Possible cause:
1. Wrong tension
2. Overloading
3. Wrong blade
4. Warped blade
Remedy:
Re 1:
Correct the blade tension
Re 2:
Lower the feed speed
Re 3:
Use narrow blades for thin material and wide
blades for thicker material
Re 4:
Do not apply any pressure to the side of the
blade
Fault:
Motor does not run
Possible cause:
1. Line fuse blown
2. Plug or power cable defective
3. Motor defective
Remedy:
Re 1:
Check the fuse
Re 2:
Replace the defective parts
Re 3:
Contact your dealer. Every attempt to repair
the machine yourself entails a certain risk.
Have repairs carried out only by an
authorized workshop.
Fault:
Vibration: Vibrations are owed to the technology
used and cannot be prevented completely.
Possible cause:
1. Bandsaw loosely mounted on the workbench or
base
2. Uneven mounting surface
3. Bandsaw table not tightened or lies against the
motor
16.10.2001 10:31 Uhr
Seite 17
4. Motor fastening screws loose
Remedy:
Re 1:
See Section 6 „Before starting"
Re 2:
The greater the dead weight of the base or
workbench, the smaller the vibration. A
workbench made of solid wood is to be
preferred to a plywood design.
Re 3:
Tighten the table fixing button; check the
table position
Re 4:
Tighten the screws
Fault:
Blade runs off the cutting line
Possible cause:
Blade guides wrongly adjusted
Remedy:
Adjust the blade guide as described in Section 7.5
„Adjusting the blade guide".
GB