8.

POWER SUPPLy UNIT INSTALLATION

The power supply unit must be installed in the electric panel or a cabinet.
The electronic inductor module may be fixed to the wall by means of bracket supply in the kit or fixed to DIN bar (2 modules, 18 mm each).
The electronic inductor module must be installed in the same electric panel as the power supply unit.
8.1.

CONNECTING THE POWER SUPPLy

8.2. DESCRIPTION OF TERMINALS

Power supply unit Ref. 1722/20
]
PriM
Mains power voltage input 100-250 Vac
}
gnd
Power voltage output
33v
Electronic inductor module Ref. 1722/112
}
gnd
Power voltage input
33v
]
line1
Bus line 1
]
line2
Bus line 2

Wall-mounted installation.
PRIM
Power supply unit
100-250Vac
1
2
Installation on DIN bar (6 modules, 18 mm each)
33V
GND
GND 33V
GND
33V
To rest of the system
DS17-06A