(maintaining any parameters that had already
been confi gured);
•
shorter than 2s or longer than 4s, the
device will be restarted.
•
after 5 short consecutive presses (at time
intervals shorter than 1s) the device will
restore its factory parameters and signal
the event with a fl ashing red/orange/green
LED light, to then switch to the confi guration
mode.
3. LAN connector: Ethernet port for wired
connection to the home network.
4. Jumpers to defi ne the type of power supply
to the device.
Power from external local power
supply (DEFAULT)
DO NOT MOVE
5. +/- 24V terminals: external local power supply
terminals.
6. LINE IN, LINE OUT terminals: connection to
the system bus.
7. Jumper Z: line termination setting.
Line termination must be activated on a
device connected at the end of a line without
a new section restarting from the LINE OUT
terminals.
Termination on (DEFAULT)
Termination off
8. CODE dip switches: these are used to defi ne
the column number.
•
1-3: Dip switches not used.
•
4-8: these defi ne the column number.
For no. 4 to 8 dip-switch settings, refer
to the System 2Voice manual.
O N
=
DS1083-121
O N
=
3.4. POWER SUPPLY (provided)
Power supply in CAT II 2500 V. Once installed, the
power supply is subject to transient voltages higher
than those of the overvoltage category for which
is was designed. For this reason, an additional
transient voltage protection is required outside the
device.
INSTALLATION
The device must be installed inside an electric
panel or cabinet.
Installation on DIN bar (2 x 18 mm modules)
1
1. N, L terminals: Input voltage 110/230 V~
2. V-, V+ terminals: Call-Forwarding device
power voltage output
3.5. PROGRAMMING AN
INTERCOM CALL FROM
THE INDOOR STATION TO
THE SMARTPHONE
(OPTIONAL)
IMPORTANT! To program the following optional
service for a specifi c user, the user must have
previously paired their CallMe app to the multi-user
call sender device.
Go to the apartment station to be programmed as
caller.
There are two different programming methods
(check which method is used in the instruction
manual supplied with the product):
1
2
2
V- V- V+ V+
NC NC N L
13