Flue Exhaust Types - Lamborghini Caloreclima LAMBY-IN 20 MCS W TOP Manual Para La Instalación Y El Mantenimiento

Caldera mural a gas para exterior - alto rendimiento - modulante
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

FLUE EXHAUST TYPES

The boiler must be installed and function outdoors. For installation use only original LAMBORGHINI parts.
LOW DYNAMIC HEAD FORCED-DRAUGHT EXHAUST KIT
(ONLY LAMBY-IN 20)
To install the low dynamic head forced draught kit insert the funnel
1 (supplied with the boiler) in the ventilator; insert the diaphragm 3
(Ø 78) and the adhesive seal 2. Fix the flanged funnel 4 with the
screws. Rest the diaphragm 5 (Ø 53) on the base of the hood 1
before installing the fume outlet flue pipe.
CONCENTRIC FLUE EXHAUST KIT
To install the concentric kit insert the funnel 1 (supplied with the
boiler) in the fan. Insert the diaphragm 3 between the adhesive seal
2 and the 5 mm spacer 4. Fix the bend 5 with the screws.
FAN-FORCED DRAUGHT FLUE EXHAUST KIT
To install the forced draught kit insert the funnel 1 (supplied with the
boiler) in the fan. Insert the diaphragm 3 and the adhesive seal 2.
Fix the flanged section 4 with the screws.
DOUBLE PIPE OUTLET KIT
To install the double pipe kit insert the funnel 1 (supplied with the
boiler) in the fan. Insert the diaphragm 3 between the adhesive seal
2 and the 5 mm spacer 4. Fix the double pipe flue exhaust 5 with
the screws.
Warning:
The boiler can only be fitted with the high double
pipe flue exhaust kit.
62
Tabla de contenido
loading

Este manual también es adecuado para:

Lamby-in 24 mcs w topLamby 20 mcs w top u/itLamby 24 mcs w top u/itLamby-in 20 mcs w top

Tabla de contenido