FLUE EXHAUST INSTALLATION
CONCENTRIC FLUE PIPE
Fit the concentric elbow pipe positioning it on the desired direction and insert on it the sealing gasket. Fit the air intake
and flue pipes, observing the distances indicated on the installation scheme. The flue pipe should slope slightly outward.
100
Max. 3000
DOUBLE FLUE PIPE
Installing an elbow to connect the boiler to the chimney will cause a drop in pressure. The values set out in the
table below indicate the necessary modifications to the length of the linear pipes.
TYPE OF INSTALLATION
Flue exhaust for fan-forced draught version (B22)
Concentric flue exhaust
Double flue pipe (intake/exhaust)
Attention: Use only air intake/ fumes evacuation kit produced by Lamborghini Caloreclima.
278
630
FLUE PIPE FOR FAN-FORCED
DRAUGHT VERSION (B22)
153
100
Max. 3000
152
SELECTING THE RIGHT AIR
DIAPHRAGM (A)
Flue exhaust for fan-forced draught version (B22) Ø78 mm.
125
Concentric flue exhaust from 0.35m to 1m Ø78 mm.
Concentric flue exhaust from 1m to 3m hole standard
Double flue pipe (intake/outlet)
Double flue pipe (intake/outlet) from 0 m to 12 m
Doubl e fl u e pipe (intake/outl e t) from 12 m to 60 m
FLUE EXHAUST FOR FAN-FORCED DRAUGHT
VERSION (B22): max length 13 m. After 5 m. it is
advisable to install a condensation collection kit.
CONCENTRIC FLUE EXHAUST: max length 3 m
DOUBLE FLUE PIPE max. length
(intake + delivery) 16,5 m. (LAMBY-IN 20) and 60 m.
(LAMBY-IN 24 max. 40 m. flue pipe). After 5 m. it is
take advisable to install a condensation collection kit.
ELBOW FITTED AT 90°
0,6 mt.
1 mt.
0,6 mt.
257
LAMBY-IN 20
hole standard
ELBOW FITTED AT 45°
65
FLUE ELBOW PIPE
Air
diaphragm (A)
LAMBY-IN 24
Ø 77 mm
Ø 77 mm
hole standard
Ø 77 mm
hole standard
0,3 mt.
0,5 mt.
0,3 mt.