Operating instructions
IN4000 Direct
Note
Tab. 3: Status
indicators of the
IN4000 Direct in
adjustment mode
Ν The LED is
illuminated
constantly.
∏ The LED is
flashing.
⌠∏ The LED is
flashing
quickly.
ν The LED is
off.
8012183/ZWH0/2018-06-05
Subject to change without notice
Product description
• If the actuating element was at the safe switch off
distance from the sensor for < 2 s (cf. Tab. 1 on
page 61) and is then brought back into the enable
zone, the yellow signal LED switches without a time
delay.
• If the actuating element is placed at the safe switch
off distance (cf. Tab. 1 on page 61) from the sensor,
the yellow signal LED extinguishes without a delay.
• If the actuating element is placed in the near range
(cf. Tab. 1 on page 61), the yellow signal LED
extinguishes with a delay of 2 s.
3.4.2
Indications in the adjustment mode
In the adjustment mode (see section 5.2 on page 74)
• the yellow signal LED flashes when the actuating
element is outside the enable zone,
• the yellow signal LED extinguishes when the actuat-
ing element is within the enable zone or in the safe
switch off range.
The output remains in the safe state in the adjustment
mode.
LED
Meaning
indication
ν Yellow
No supply voltage
ν Green
ν Yellow
Undervoltage
∏ Green
ν Yellow
Overvoltage
⌠∏ Green
© SICK AG • Germany • All rights reserved
Chapter 3
Output state of the
outputs
OUT1
OUT2
(OSSD1)
(OSSD2)
0
0
0
0
0
0
en
63