Fall Clearance

The following fall clearance chart is a sample chart only, illustrating a 6ft (1.8m) shock absorbing lanyard with the
Miller DuraHoist
Portable Fall Arrest Post and Miller TechLine
TM
Always know your fall distance and select proper equipment to meet the fall clearance. Remember, under 18 1/2
ft (5.6m) always use a self-retracting lifeline and over 18 1/2 ft (5.6m) a shock-absorbing lanyard or self-retracting
lifeline can be used. Always calculate your fall distance before selecting your fall protection equipment.
8.0 Storage, Maintenence & Inspection
Storage
The Portable Fall Arrest system should be completely inspected/maintained prior to storage. If damage or wear is
detected, remove from service and mark "DO NOT USE" until repaired.
Steps to follow prior to storage:
1.
Clean debris/dust/contaminants from the system using mild soapy water. Ensure all labels are legible & intact.
2.
If HLL is used, clean it using a neutralizing solution, especially if the lifeline has been used in a corrosive or
toxic environment.
3.
Perform complete and thorough inspection, documenting the results.
4.
Touch up any scratches, etc. to help prevent corrosion.
5.
Store in a cool dry location. (If using storage bags, ensure unit is completely dry).
Us er Instru cti o ns - E ng l i sh
kit for horizontal lifeline application.
TM
15