INSTALLATION
+
Blue
Green
PAUSE
White
FLOW SWITCH
Black
1. Connect signal wires as required by the installation:
SECONDS
FLOW SWITCH
PAUSE
Green & White
AUXILIARY
- For AC signal, there is no polarity.
- For DC signal, blue wire is connected to signal positive (+) and brown (or orange)
is connected to signal negative (—).
NOTE: If polarity is reversed when connecting a DC signal to the AUX input, the
pump will not respond to the signal.
2. Cap all non-terminated wires.
NOTE: All non-terminated wires must be capped to prevent operational errors or damage to
the pump.
3. Plug power supply into receptacle. The cover must be removed to program the pump.
Remove the self-tapping Phillips head screw and slide the cover off. To unlock the
keypad, simultaneously press and hold
4. Put the pump in standby. First, press and continue to hold
5. Program the pump for the desired operating mode and % setting, refer to Program
Pump Settings in the manual. After programming, slide the cover on and reinstall
the screw.
NOTE: Leave the unit in standby until the signal wires are connected and the pump is
ready for priming.
Brown
(or Orange)
AUXILIARY
SECONDS or
Black & Red
Black & Red
Brown (or Orange) & Blue
USA and Canada 800.683.2378, International 904.641.1666
and
for 5 seconds.
%
MODE
, then press
MODE
Econ FP
.