FLOW SWITCH
PROGRAM PUMP SETTINGS
1. Calculate the Pump Speed Percentage Setting.
Metering Pump Output Requirement (gpd) x 100
Metering Pump Maximum Output (gpd)
2. Program the Pump Operating Mode and the Pump Speed Percentage.
Unlock the Keypad
Press
and
MODE
Pump Operating Mode
First, press and continue to hold
the modes of operation. When the display shows FLOW SWITCH, release both buttons to
select. The operating mode is now set.
Pump Speed Percentage
The pump speed can be programmed from 10% to 100% in 1% increments. First,
press and continue to hold
percentage determined in #1. When the display shows the desired percent, release
both buttons to select. The percentage is now set.
18
Econ FP
(dry contact signal)
%
simultaneously and hold for 5 seconds to unlock the keypad.
MODE
, then press
%
FLOW SWITCH 10%
+ +
KEYPAD LOCKED
Example of control panel with keypad locked.
FLOW SWITCH 10%
Example of control panel set for 10% in Flow switch mode.
www.stenner.com
= Pump Speed Percentage Setting
, then press
or
+ +
or
to scroll through
to adjust the speed