SECONDS MODE
PROGRAM PUMP SETTINGS
4. Program the Pump Operating Mode and the Pump Operating Time Percentage.
Unlock the Keypad
Press
and
MODE
Pump Operating Mode
First, press and continue to hold
shows 1, 5, 10, 20 or 60 SECONDS, release both buttons to select based on the
pump operating time determined in #2. The operating mode is now set.
Pump Operating Time Percentage
The pump operating time can be set from 10% to 100% in 1% increments. First,
press and continue to hold
operating time percentage determined in #3. When the display shows the desired
percent, release both buttons to select. The percentage is now set.
For example, if the pump is set in the 60 seconds mode and the setting is 50%, the pump will run for
30 seconds when it receives a signal from the water meter
(dry contact signal)
%
simultaneously and hold for 5 seconds to unlock the keypad.
MODE
, then press
%
60 SECONDS 50%
+ +
KEYPAD LOCKED
Example of control panel with keypad locked.
60 SECONDS 50%
Example of control panel set for 50% of 60 seconds.
USA and Canada 800.683.2378, International 904.641.1666
, then press
or
.
+ +
continued
or
; when the display
to adjust the pump