INSTALLATION
MOUNT PUMP
Select a dry location (to avoid water intrusion and pump damage) above the
solution tank.
NOTE: A mounting template is provided on page 37.
To prevent pump damage in the event of a pump tube leak, never mount the
pump vertically with the pump head up.
DO NOT mount pump directly over an open solution tank. Keep tank covered.
Avoid flooded suction or pump mounted lower than the solution container. Draw
solution from the top of the tank. Pump can run dry without damage. If pump is
installed with a flooded suction, a shut-off valve or other device must be
provided to stop flow to pump during service.
To prevent damage to the pump, verify with a volt meter that the receptacle
voltage corresponds with the pump voltage.
For outdoor installation, the pump must be mounted vertically
to comply with the outdoor rating.