4. CONNECTORS DESCRIPTION
XC30 Connector: Digital Outputs
-
+ -
(*)
+
RL ≥ 500 Ω
(*) The internal 24Vdc power supply can be used by connecting XC30:9 to XC31:5 and XC31:4 to the
load.
4
XC30
1
NC
Not connected
2
NC
Not connected
3
NC
Not connected
4
NC
Not connected
5
NC
Not connected
6
NC
Not connected
7
NC
Not connected
8
NC
Not connected
Common to digital outputs
9
COM DO
DO104, DO105 and DO106
10
NC
Not connected
11
NC
Not connected
12
NC
Not connected
13
NC
Not connected
14
NA103
Digital relay output DO103
15
C103
16
DO104
Bidirectional opto-isolated
17
DO105
digital outputs
18
DO106
Figure 5: Description of XC30 connector
Function
Contact capacity:
Maximum voltage: 250 VAC
Maximum current : 3 A
NO – Normally open;
C – Common.
Maximum voltage: 24 VDC
Maximum current : 500 mA
Specifications
-
-
-
-
-
-
-
-
-
-
-
-
-