Dometic FRESHJET FJ 1100 Instrucciones De Montaje página 23

Ocultar thumbs Ver también para FRESHJET FJ 1100:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 80
FreshJet
Remote light switch (not included in the scope of delivery)
You can connect the lighting to a remote light switch. This enables you to switch on
the lighting remotely.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (3) from the socket on the circuit board of the air outlet
unit.
➤ Connect the two cables of the remote light switch to the 2-pin plug (3).
➤ Insert the 2-pin plug (3) into socket on the circuit board.
12 Vg cable
You can connect the lighting to the battery. This enables you to switch on the lighting
even if the 230 Vw voltage supply is not connected.
To do this, proceed as follows:
➤ Disconnect the 2-pin plug (4) from the socket on the main board.
➤ Connect the positive cable (5) with the plug.
➤ Connect the negative cable (6) with the plug.
Connecting the circuit board
➤ Insert the 12-pin plug (8) in the socket (7) on the circuit board of the air outlet unit.
See fig. c
➤ Choose the suitable seal in accordance with the following table:
Roof thickness
25 – 30 mm
30 – 40 mm
40 – 60 mm
➤ Position the seal with the adhesive side on the ADB.
➤ Fasten the fastening frame (3) on the underside of the roof air conditioner with
the 4 screws supplied.
EN
Seal type
15 mm
30 mm
45 mm
Installation