PD Telegram select
p0922 (999)
Interconnection
is made
according to
Telegram
20
Appl. class
1
PZD1
STW1
ZSW1
STW2_ENC
PZD2
NSOLL_A
NIST_A_GLATT
G1_STW
PZD3
IAIST_GLATT
PZD4
MIST_GLATT
PZD5
PIST_GLATT
PZD6
user <3>
PZD7
PZD8
PZD9
PZD10
PZD11
PZD12
PZD13
PZD14
PZD15
PZD16
PZD17
PZD18
PZD19
PZD20
PZD21
PZD22
PZD23
PZD24
PZD25
PZD26
PZD27
PZD28
PZD29
PZD30
PZD31
PZD32
<1> Depending on the drive object, only specific telegrams can be used. Not suitable for sensorless vector control.
<2> If p0922 = 999 is changed to another value, the telegram is automatically assigned as specified in [2415] - [2423].
If p0922
999 is changed to p0922 = 999, the "old" telegram assignment is maintained as specified in [2415] - [2423].
<3> Freely interconnectable (pre-setting: MELD_NAMUR).
<4> The maximum number of PZD words depends on the drive object type.
<5> Only for ENCODER.
= Position encoder signal
1
2
DO: ENC, SERVO, VECTOR
PROFIdrive - Standard telegrams and process data 2
<5>
<5>
81
82
1
1
ZSW2_ENC
STW2_ENC
ZSW2_ENC
STW2_ENC
G1_ZSW
G1_STW
G1_ZSW
G1_STW
G1_XIST1
G1_XIST1
G1_XIST2
G1_XIST2
NIST_A
3
4
[2440] [2450] automatically
<5>
83
1
ZSW2_ENC
G1_ZSW
G1_XIST1
G1_XIST2
NIST_B
5
6
fp_2416_54_eng.vsd
06.03.14 V04.07.00
PROFIdrive sampling time
7
8
Function diagram
- 2416 -
S120/S150/G130/G150