37 00
Management of last section of travel
00
OFF
01
05
leaf length (1=0.5m, 2=1m, 3=1.5m, 4=2m, 5=2.5m or more)
-
When this function is set, torque is decreased while the gate is opening for the very last section of travel,
thus reducing the vibration generated when the leaf reaches the gate stop. While closing, operation will
vary depending on whether an electric lock is fitted or not: if fitted (parameters
torque to ensure the electric lock closes; if not fitted, it decreases torque to avoid vibration.
The parameter is only visible if the encoder is enabled (
38 00
Opening jolt
00
DISABLED
01
04
time in SECONDS
-
A-
NOTE: parameter
This function is enabled to help release the electric lock, which might be impeded by the leaf pushing
against the latching point (as a result of wind, for example): gate opening starts with a small closing push,
the duration of which can be selected with this parameter.
When the opening jolt feature and electric lock are enabled (par.
1-second early release (par.
where necessary, you can alter it manually.
The opening jolt is performed for the set time only when starting from the fully closed position; while the
leaf is in an unknown position, or where no limit switches or encoder are fitted, it is performed every time
the gate is opened, applying the closing push for 1" before opening.
41 01
Slow-down option
00
slow-down disabled
01
medium slow-down
02
maximum slow-down (never choose this value for 6-pole motors)
42 20
Encoder obstacle sensing sensitivity during normal travel
43 50
Encoder obstacle sensing sensitivity during slowed travel
01
99
PERCENTAGE (1=no sensitivity, ......, 99=maximum sensitivity)
-
NOTE: movement is reversed when the speed detected is less than the set value
Selecting a low percentage value for these parameters makes obstacle sensing - based on encoder signals
- less sensitive. The factory default setting is a value chosen to ensure good reliable operation under all
conditions, meaning sensitivity is quite low.
Movement is reversed immediately on sensing an obstacle.
WARNING!!! For 6-pole motors, set a value below
49 00
Auto-closing attempts after safety edge or anti-crush device is triggered
00
gate does not auto-close after safety edge or anti-crush device is triggered
01
03
number of closing attempts
-
If this value is higher than the value set for parameter
value set for parameter
back to the fully open position.
38
in easy setup mode.
28
) and 3-second release time (par.
a2
. Closing only takes place following a collision if the leaf has reversed all the way
75 01
).
79
), the unit automatically activates the
29
). This setting is selected automatically;
60
a2
, it will automatically be regarded as equal to the
28
29
and
), it increases