CONTENTS
1

Introduction to instructions and warnings

This manual is intended for use by technical
personnel who are qualified to install the
equipment.
None of the information herein can be deemed of
interest to the end user.
This manual refers to H70/200AC control units
for automation systems comprising 1 or 2
asynchronous single-phase 230Vac motors and is
not to be used for devices of any other kind.
Page
25
26
WARNINGS
26
27
Read the instructions carefully before commencing
27
installation.
To avoid the risk of electrocution and physical
27
injury, always disconnect the power supply before
27
performing work on the device.
28
Installation must be carried out by qualified
28
technical personnel only according to current code.
28
When making connections, use cables appropriate to
28
the current and voltage ratings and heed the product's
28
technical specifications. Ensure that the earthing
29
system is to code and check continuity between the
earth on the motor side and the unit's terminal block.
30
Loads connected to COR (courtesy) and LAM (flashing
light) contacts must be protected with a 5x20 fast-
30
blow fuse with a maximum rating of 1A 250V.
30
If you are connecting an electric lock, do not power
31
it with the accessory output: instead, use an external
power supply with a suitable voltage and power rating.
31
Removing the fuse protecting the 24Vac loads
(F2) cuts off power to the photocells and relays
but does not cut off power to the control part
and the message
Consequently, this method cannot be used to
32
reset the microcontroller; if you need to reset - for
32
instance, after editing parameters that redefine the
33
gate structure (number of leaves, encoder/limit
33
switch fitted) - disconnect the 230Vac power supply
33
completely and wait for the display to go off, then
power up the control unit again.
43
43
NOTE: use the same type of motor for both leaves.
43
130
2

Product description

The H70/200AC unit can control any asynchronous
motor provided its technical specifications match
the manufacturer's stated specifications.
When using motors equipped with encoders, the
control unit can determine the position of the leaf
based on the information received and detect when
the gate hits an obstacle.
You
can
connect
pushbutton control stations, key selectors, a flashing
light, a radio receiver, a gate open light, an electric
lock, a courtesy light and a timer. There are two
setup levels: a simple option to meet the needs
of most installations and a full (advanced) option
that gives you ample opportunity to tailor the
automation system's behaviour to individual needs.
ELECTROCUTION
HAZARD
24 AC
will flash on the display.
photocells,
safety
EN
edges,
25