Available Accessories; Remote Control; Recycling; Troubleshooting - Zodiac Z300 Manual De Instalación Y De Uso

Ocultar thumbs Ver también para Z300:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 50

4.2 Available accessories

Name
PAC NET
Representati on

4.3 Recycling

This symbol means that your appliance must not be disposed of as household waste. It will be subject to selecti ve
waste sorti ng with a view to its reuse, recycling or sale. If it contains substances that are potenti ally harmful to the
environment, they will be eliminated or neutralised.
Ask your reseller for informati on about recycling.
5. Troubleshooti ng

5.1 Displays

Display
Designati on
Protecti on of heat
exchanger in cold
mode
High temperature
defect for the
evaporator in
«cooling» mode
Phase order defect
(only on three-
phased models)
Refrigerant circuit
low pressure defect
Refrigerant circuit
high pressure defect
Compressor
discharge
temperature defect
Control sensor
defect (ST1)
Water fl ow-rate
sensor defect (ST4)
Defrost sensor
defect (ST3)
9
Remote
Wintering cover
control
Cause
Temperature of ST4
sensor too low
Temperature probe ST3
above 60°C or evaporator
scaled up
• Wiring incorrect on the
supply terminal board
of the device,
• Modifi cati on of phase
order by electrical
supplier,
• Temporary failure of
one or several phases
Low pressure circuit
pressure defect (if the
defect remains aft er
reset)
• Water and air mixture
passing in the appliance,
• Unsati sfactory water
fl ow,
• Blocked fl ow controller
• Clogged or blocked heat
exchanger
Compressor discharge
temperature too high
Sensor out-of-order or
disconnected (connector
J2 red on plate A1)
Sensor out-of-order or
disconnected (connector
J8 white on plate A1)
Sensor out-of-order or
disconnected (terminals
1-2 of connector J3 white
on plate A2)
Technical room
Condensate pan
kit
Soluti on
Wait for the surrounding
Automati c
temperature to become
warmer
Clean the evaporator,
Automati c if
if the defect persists,
temperature probe ST3
contact an approved
is below 45°C
technician
• Reverse the phases on
Switch the power
the supply terminal
supply off or press
board (without power
to the device)
• Contact your electricity
provider to fi nd out
if modifi cati ons have
been made to your
equipment.
Contact an approved
Automati c reset (for
technician
less than 4 defects per
hour) or press
• Check the pool
Automati c reset (for
hydraulic circuit
less than 4 defects per
• Increase the fl ow-rate
hour) or press
using the by-pass, check
that the pool fi lter is
not clogged)
• Check the fl ow-rate
controller
• Clean the exchanger
• If the defect persists,
contact an approved
technician
Contact an approved
Press
technician
Replace or reconnect the
Switch the power
sensor
supply off or press
Replace or reconnect the
Switch the power
sensor
supply off or automati c
reset if the defect
disappears
Replace or reconnect the
Switch the power
sensor
supply off or press
H0439100.C - EN - 2015-01
Reset
for 3 seconds
Tabla de contenido
loading

Tabla de contenido