19. Lock Strike Relay and Auxiliary Relay Code
Assignment using the Standard Method When a Primary Code is enrolled for any user, that user is assigned rights to
activate the Lock Strike Relay when they present a valid code to the controller. The Code Assignment Menu allows
you to assign whether the Lock Strike Relay and/or the Auxiliary Relay is activated when a user enters a valid code.
There are two methods to Assign Codes, Standard Method and the Code Search Method.
19.1 Relay Code Assignment using the Standard Method
1. Enter Programming Mode
2. Press "9" to enter Menu 9: the Mode LED will turn green.
3. Enter the 3-digit User Slot that you want to assign a code to: The Mode LED will flash green.
4. Enter the assignment digit for the current User Slot: "1" assigns the Lock Strike Relay only "2" assigns the Auxiliary
Strike Relay only "3" assigns the Lock Strike and Auxiliary Relay
5. If the assignment code is valid the Mode LED will stop flashing and the ZD08 is now waiting for another slot number.
Press the "#" key to go to the next slot, press the "#" key twice to return to Normal Mode.
19.2 Relay Code Assignment using the Code Search Method
1. Enter Programming Mode
2. Press "9" to enter Menu 9: The Mode LED will turn green.
3. Enter the 3-digit User Slot 000: The Door LED will flash orange.
4. Enter the 4-digit PIN Code of the Primary Code belonging to the user you want to assign a code to: The Mode LED
will flash green.
5. Enter the assignment digit for the current User Slot: "1" assigns the Lock Strike Relay only "2" assigns the Auxiliary
Strike Relay only "3" assigns the Lock Strike and Auxiliary Relay
6. If the assignment digit is valid the LED 'Mode' will stop flashing and the ZD08 is now waiting for another slot number.
Press the "#" key to go to the next slot, press the "#" key for 2 seconds to return to Normal Mode.
20. Enabling or Disabling the built-in keypad heater
The ZD08 contains a built-in keypad heater. When is enabled the keypad heater will activate when the ambient tem-
perature drops to approx. 3C to 5 C and will remain active until the keypad temperate rises to approx 5 C to 8 C. When
the heater is enabled the ZD08 is lowest operating temperature is -20 C, otherwise is 0°C; When the built-in keypad
heater is active it will require additional power.
The factory default setting for the keypad heater is disabled, to changing it:
1. Enter Programming Mode.
2. Press "6" to enter Menu 6: the Mode LED will flash green.
3. Construct the digit code 3 0 0 and the fourth digit as follows:
"0" to DISABLE the heater
"1" to ENABLE the heater
21. Replacing a lost Programming Code
NOTE: The ZD08 must be in Normal Mode otherwise this will not work. Make sure that the Mode LED is green before
proceeding
1. Remove power
2. Press the REX button
3. Apply power to the unit with REX button pressed
4. Release the REX button
5. Within 15 seconds enter programming mode by pressing # twice, enter the standard programming of default (see
table par.8)
6. Press 3 to access the programming code modification function
7. Enter the new programming code.
8. The ZD08 returns to Normal mode: the 'Door' LED switches off and the 'Mode' LED turns green.
22. Replacing a lost Normal / Secure Code
NOTE: The ZD08 must be in Secure Mode otherwise this will not work. Make sure that the Mode LED is red before
proceeding.
1. Remove power
2. Press the REX Button
3. Apply power to the unit with REX button pressed
4. Release the REX Button
5. You now have 15 seconds to use the default Normal/Secure Code 3838 in order to return to normal mode, where
you may enter programming mode and enter a new Normal/ Secure Code (see par. 13).
14
Mode
Door
GREEN
Mode
Door
ORANGE
GREEN
?
?
?
Mode
Door
GREEN
ORANGE
Mode
Door
GREEN
Mode
Door
ORANGE
GREEN
0
0
0
Mode
Door
ORANGE
GREEN
?
?
?
?
Mode
Door
ORANGE
GREEN
Mode
Door
GREEN
Mode
Door
GREEN GREEN
0
0
0
3
EN
Tabla de contenido
loading

Tabla de contenido