Vimar Elvox ZD08 Manual Para El Conexionado Y El Uso página 10

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 34
1. INTRODUCTION
The ZD08 is a vandal resistant keypad access control unit suitable for external applications.The unit accepts up to 500 users and provides entry via the use
of PIN codes. Model ZD08 is provided with LED backlight.
2. MAIN TECHNICAL FEATURES
Operating Voltage Range: 12-24 VAC/DC
Maximum Input Current:
without heating: 20 mA in standby -- 115 mA max, with backlight 50 mA in standby - 145 mA max.
(ZD08 only): 50mA in standby -- 145mA max
with heating, 12Vcc: 520mA in standby – 615 mA max
with heating, 24Vcc: 350mA in standby – 465 mA max
"A" (Electric lock) Relay: Form C, 2A
Auxiliary "B" Relay: Form C, 2A
Inputs: REX N.O. , clean contact, LOCK-AUT, and N.C. clean contacts.
Operating Temperature:
Keypad Heater Enabled: da –20 °C a 63 °C
Keypad Heater Disabled: da 0 °C a 63 °C
IP protection degree: IP 65
Dimensions: 120mm x 76mm x 21mm
Weight: 410 g
3. MOUNTING
Before starting, select the location to mount the ZD08 controller.This location should be at shoulder height and on the same side as the door handle. For
fixing, drill two holes, in correspondence of the two points marked as A, in case of 3 modules box or on the 4 points indicated with the letter "B" in case of a
flush-mounted back box Ø 60 type ZX26. Drill in correspondence of sign C for the passage of cables.
1. Wire the controller according to the wiring instructions on thefollowing page.
2. Screw the ZD08 back cover to its mounting location.
3. Return the front cover of the ZD08 to the mounted back plate.
4. Secure the front cover by using the security screw. An L-Shaped tool is provided with the fixing screws for use when tightening the security screw.
3.1 Wiring the ZD08
The controller is supplied with a 1 m pigtail, having a 10 conductor cable.
To wire the ZD08, perform the following steps.
1. Prepare the controller cable to the required length.
2. Splice the controller pigtail wires to the corresponding devices and cover
each connection. Refer to the wire color guide provided below and to the
wiring diagrams provided on the following pages.
3. Trim and cover all conductors that are not used.
CONDUCTOR COLOUR
RED
BLACK
GREEN
WHITE
VIOLET
GREY
BROWN
SKY BLUE
YELLOW
ORANGE
4. NORMAL, SECURE & MASTER USERS
The ZD08 accepts up to 500 users and provides entry via the use of PIN codes. Each user is provided with two code memory slots, Memory Slot 1 (Primary
Code) and Memory Slot 2 (Secondary Code). The way in which the two memory slots are programmed determines a users access level and also determines
the way in which the ZD08 grants access in its three Modes of Operation.
There are two user levels:
Normal User
A Normal User only has a Primary Code and is only granted access when the ZD08 is in Normal or Bypass Mode.
Secure User
A Secure User must have a Primary and Secondary Code programmed, the two codes must not be the same. The Secure User
can gain access when the ZD08 is in any of its three Modes of Operation. In Normal Mode the Secure User must use their Primary Code to gain entry. In
Secure Mode the Secure User must present both their Primary and Secondary Codes in order to gain entry.
8
DESCRIPTION
+ supply voltage (Vinput)
- earth (Ground)
N.O. clean contact (REX)
To activate the "A" relay by means of push-button.
N.O. clean contact (REX)
To activate the "B" relay by means of push-button.
Common (Relay "A")
N.O. (relay "A")
N.C. (relay "A")
Common ("B" relay)
N.O. (relay "B")
N.O. ("B" relay)
CAUTION! DO NOT DRILL
This is the Tamper Lens
A
B
B
C
B
B
A
EN
Tabla de contenido
loading

Tabla de contenido