6. Auxiliary Input and Output
The ZD08 auxiliary input and output can be configured in different combinations, for optimum usability in different applications. (see par.15).
7.
Manual control push-button
The REX button must be located inside the premises to be secured and is used to open the door without the use of a proximity card or PIN code, it is usually
located in a convenient location, e.g. Inside the door or at a receptionist's desk. The function of the REX button depends on whether the Lock Strike Relay is
programmed for Fail Safe Operation or Fail Secure Operation.
1. Fail Secure Operation: From the moment the REX button is pressed, the door will be unlocked until the "Lock Strike Release Time" has passed. After this
time, the door will be locked even if the REX button has not been released.
2. Fail Safe Operation: From the moment the REX button is pressed, the door will be unlocked until the REX button is released, plus the "Lock Strike Release
Time". In this case the "Lock Strike Relay" only begins its count down once the REX button has been released.
Connections:
-
"A" (lock) manual relay command
-
Green conductor (N.O.)
-
Black contact (Earth)
-
"A" (lock) manual relay contact
-
Green conductor (N.O.)
-
Black contact (Earth).
8. Programming the ZD08
Programming the ZD08 is done solely via the unit's keypad driven
Programming Menu System (see par.8.1).Certain codes and settings are pre-programmed with Default Factory Settings. The table below shows the names
of all the ZD08 Menus, default factory codes and settings.
Factory
Menu description
settings
2580
Change Open Code
Change Auxiliary Code
0852
1234
Change Program Code
3838
Change Normal / Secure Code
-
Change Normal / Bypass Code
0004
Change Door Release Time
2004
Define Auxiliary Inputs / Outputs
3000
Enabling the built-in keypad heater
2100
Changing the backlight and LED behavior
Enroll Proximity Cards, PIN Code or both
-
-
Delete Proximity Cards Or PIN Code
-
Code Assignment with Strike/Auxiliary
-
Return to Default Factory Setting
8.1 Entering Programming Mode
1. Press the "#" key two times. Mode LED will turn off. Door LED will turn red.
2. Enter your 4-digit Programming Code.
3. If the Programming Code is valid the door LED will turn green and the ZD08 will be in Programming Mode.
NOTE
-
The ZD08 must be in Normal Mode to enter the Programming Mode.
-
The factory default Programming Code is 1234
-
If a Programming Code is not entered within 5 seconds, the ZD08 will return to Normal Mode.
8.2 To exit the Programming Mode
1. Press the "#" key twice, you will hear a long beep.
2. The Door LED will be off and the Mode LED will turn green, the ZD08 has returned to Normal Mode
NOTE
-
Wrong entries may reset the controller back to Normal Mode.
-
While in Programming Mode if no key is pressed for 1 minute the ZD08 will exit programming mode and
return to Normal Mode.
10
(REX)
Menu
number
1
2
3
4
5
6
6
6
6
7
8
9
0
Par.
10
11
12
13
14
16
15
20
9
17
18
19
23
Mode
Door
RED
3
4
2
1
Mode
Door
GREEN
EN