<Navigating through the pages>
page
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
<Saving the settings>
OU silent mode
Mon
Tue Wed Thu Fri Sat Sun
Start
Stop
Silent
-
Setting display:
day
F1
F2
F3
F4
<Exiting the Main menu screen>
Fri
Room
Cool
Set temp.
Auto
Mode
Temp.
Fan
F1
F2
F3
F4
<Display of unsupported functions>
Title
Not available
Unsupported function
Return:
F1
F2
F3
F4
<Accessing the menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
Press [F3] to go to the previous
page.
Press [F4] to go to the next page.
Select the desired item, and press
the [SELECT] button.
The screen to set the selected item
will appear.
Press the [RETURN] button to exit
the Main menu and return to the
Main display.
If no buttons are touched for
10 minutes, the screen will
automatically return to the Main
display. Any settings that have not
been saved will be lost.
The message at left will appear if
the user selects a function not sup-
ported by the corresponding indoor
unit model.
Select "Vane·Louver·Vent. (Loss-
nay)" from the Main menu (refer to
page 8), and press the [SELECT]
button.
<Vane setting>
Fri
Swing
Off
Off
Vane
Vent.
Louver
F1
F2
F3
F4
Fri
Room
Cool
Set temp.
Auto
Mode
Temp.
Fan
<Vent. setting>
Fri
Low
Vent.
F1
F2
F3
F4
<Returning to the Main menu>
Main
Main menu
Vane·Louver·Vent. (Lossnay)
High power
Timer
Weekly timer
OU silent mode
Main display:
Cursor
Page
F1
F2
F3
F4
Note:
During swing operation, the directional indication on the screen
does not change in sync with the directional vanes on the unit.
Available directions depend on the type of unit connected.
In the following cases, the actual air direction will differ from the
direction indicated on the remote controller display.
2. Immediately after starting heat mode (while the system is wait-
ing for the mode change to take effect).
perature setting.
Press the [F1] or [F2] button to go
through the vane setting options:
"Auto", "Step 1", "Step 2", "Step 3",
"Step 4", "Step 5" and "Swing".
Select the desired setting.
Auto
Auto
Step 1
Step 2
Step 3
Step 4
Step 5
Swing
Swing
Select "Swing" to move the vanes
up and down automatically.
When set to "Step 1" through "Step
lected angle.
under the vane setting icon
This icon will appear when the
vane is set to "Step 2" to "Step 5"
and the fan operates at "Mid 1"
to "Low" speed during cooling or
dry operation (depends on the
model).
The icon will go off in an hour, and
the vane setting will automatically
change.
Press the [F3] button to go through
the ventilation setting options in the
order of "Off", "Low", and "High".
* Settable only when LOSSNAY
unit is connected.
Off
Low
High
Off
Low
door units may be interlocked
with certain models of ventilation
units.
Press the [RETURN] button to go
back to the Main menu.
9
-
High
-
-