Alliance Laundry Systems AT120FG Manual Del Usuario página 54

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Adjustments
CE Marked Models
The loading door switch is factory adjusted to turn
off tumbler when the door is opened a maximum
of 3 inches (76.2 mm). If adjustment is needed, refer to
Figure 24 and follow these steps.
1. Start tumbler, following the operating
instructions which accompanied it.
2. Slowly open loading door. Cylinder and heating
system should stop when door is open 3 inches
(76.2 mm) maximum.
3. Slowly close loading door while depressing start
switch or pad. Tumbler should start before
loading door is 0.5 inch (13 mm) from fully
closed.
4. If opening the loading door 3 inches (76.2 mm)
maximum does not stop tumbler, adjust switch.
a. Loosen lower screw on switch coupler (use
2 mm hex wrench).
b. Align screw slot with alignment marks on
switch top (switch should be closed, or on).
c. Start tumbler.
d. Prop door open 2.5 inches (63.5 mm).
e. Slowly rotate switch coupler
counterclockwise (viewed from above switch)
until tumbler stops.
f. Tighten lower screw on switch coupler.
g. Return to step 1 to verify loading door switch
operation.
52
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
1
Loading Door Switch
2
Screw Slot
3
Switch Coupler
Figure 24