Gas Requirements
High Altitude Orifice Sizing
For proper operation at altitudes above 2000 feet
(610 meters), the gas orifice size must be reduced to
ensure complete combustion. For CE Marked models,
consult local gas supplier.
Model
Gas
Natural
Gas
8001 – 10,000
120FG
L.P.
Gas
8001 – 10,000
Natural
Gas
170FG
8001 – 10,000
L.P.
Gas
* Btu/hr derate of 4% per 1000 ft. (305 m) of altitude.
38
Non-CE Marked Models
Altitude
feet
m
2001 – 4000
610 – 1220
4001 – 6000
1221 – 1830
6001 – 8000
1831 – 2440
2441 – 3050
2001 – 4000
610 – 1220
4001 – 6000
1221 – 1830
6001 – 8000
1831 – 2440
2441 – 3050
2001 – 4000
610 – 1220
4001 – 6000
1221 – 1830
6001 – 8000
1831 – 2440
2441 – 3050
2001 – 6000
610 – 1830
6001 – 8000
1831 – 3050
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Orifice
No.
inches
mm
Quantity
14
0.1820
4.6
16
0.1770
4.5
17
0.1730
4.4
19
0.1660
4.2
35
0.1100
2.8
36
0.1065
2.7
38
0.1015
2.6
40
0.0980
2.5
14
0.1820
4.6
16
0.1770
4.5
17
0.1730
4.4
19
0.1660
4.2
30
0.1285
3.3
31
0.1200
3.0
Table 6
New
Rate
Part No.
(Btu/hr)*
M411371
276,000
M411373
252,000
M411374
228,000
M402995
204,000
3
M402487
276,000
M411375
252,000
M411376
228,000
M406361
204,000
M411371
363,400
M411373
331,800
4
M411374
300,200
M402995
268,600
M401021
363,400
3
M401017
300,200
M414038