Steam Requirements
170 Pound Tumblers
SUPPLY
7
6
5
NOTE: Sizing of pipe diameters is shown for steam at rated pressure of 120 psi. Pipe diameter needs to be increased
accordingly if pressure is less than 125 psi (refer to Table 9). Piping must also be sized accordingly for length of runs
and number of elbows.
1
Risers 12 in. (305 mm)
2
Shut-Off Valve
3
Check Valve
4
Vacuum Breaker
5
Condensate Return Line from Supply Line
Model
170CSH
170CSH
170CSH
44
2
8
4
3
Steam Pressure
(psi)
110 – 125
60 – 110
35 – 60
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
1
9
3
10
6
18 in. Drop (457 mm)
7
Steam Bonnet
8
Solenoid Valve (Supplied with machine)
9
Union
10
Trap with Built-In Strainer
Figure 17
Minimum Pipe Diameter
1 in. (25 mm)
1.25 in. (32 mm)
1.5 in.(38 mm)
Table 9