To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Undo the screw (D).
4)
Set the burner mount (E) at a distance of 17
5)
mm , and tighten the screw (D).
Replace the control panel (B) and the knob (A)
6)
on completion of the operation.
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Undo the screw (D).
4)
Set the burner mount (E) at a distance of 20
5)
mm, and tighten the screw (D).
Replace the control panel (B) and the knob (A)
6)
on completion of the operation.
GB
To carry out this operation, proceed as follows.
Turn off the gas supply tap.
1)
Pull off the knob (A).
2)
Undo the screws (C) and remove the control
3)
panel (B).
Undo the screw (D).
4)
Set the burner mount (E) at a distance of 20
5)
mm, and tighten the screw (D).
Replace the control panel (B) and the knob (A)
6)
on completion of the operation.
3319990_inst_rev.2_GB
ADJUSTING TOP BURNER PRIMARY AIR (4 KW)
ADJUSTING TOP BURNER PRIMARY AIR (7 KW)
ADJUSTING TOP BURNER PRIMARY AIR (10 KW)
A
B
A
B
A
B
- 14 -
C
C
C
C
C
C
D
D
D
ENGLISH