Electrical Connection; Conversion Of Gas Supply - Angelo Po 1N1FAGV Manual De Uso

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Important
The equipment comes with a cable to con-
nect it to the outlet of the disconnecting
switch. If it is necessary to change the cable,
proceed as described below.
Important
The connection must be made by authorised,
skilled personnel, in accordance with the rele-
vant legal requirements, using appropriate and
specifi ed materials.
The appliance is supplied with operating volta-
ge 230V1~N 50 Hz.
If not already present, install a circuit-breaker
1)
close to the appliance, with the following
(A)
characteristics.
– Thermal breaker device (to adjust see table An-
nexes).
– Magnetic circuit breaker curve B (IEC 60898-1).
– Residual current protection set at mA 30.
Pull off the knob (B).
2)
Undo the screws (C) and remove the control
3)
panel (D) to access the electric box (E).
Undo the screw (F) to remove the lid (G).
4)
Caution - Warning
Before doing any work, cut off the mains
electricity supply.
The manufacturer has tested the appliance with
its own mains gas, identifi ed by the sticker ap-
plied to the nameplate.
If the type of gas to be connected is diff erent
from that used for testing, proceed as follows.
Turn off the gas supply tap (A).
1)
Change the top burner nozzles (see page 13-
2)
14).
3319990_inst_rev.2_GB

ELECTRICAL CONNECTION

5)
– Weight: ≥ than H05RN-F type (designation 245
Temperature of use: ≥ 70°C.
When connecting, take care to connect the
neutral and earth lines.
6)

CONVERSION OF GAS SUPPLY

- 11 -
C
B
C
D
Connect the circuit-breaker (A) to the terminal
board(H) as shown in the diagram and in the
electrical system diagram at the back of the
manual and using a cable with the following:
IEC 57).
Important
Replace all when the operation is complete.
A
A
G
E
F
ENGLISH
GB
Tabla de contenido

Solución de problemas

loading