18.3
Connection of the motors with preassembled cables
Wiring diagrams can be found in chapter "Wiring Diagrams" from p.87.
l
l
l
l
l
Requirements to cable material:
Capacity
Motor cable
Resolver cable
For a detailed description of preassembled cables, please refer to the accessories manual.
Servomotors AKM
06/2010
Carry out the wiring in accordance with the valid standards and regulations.
Only use our preassembled shielded cables for the resolver and power connections.
Connect up the shielding according to the wiring diagrams in the instructions manual
for the servo amplifier.
Incorrectly installed shielding inevitably cables to EMC interference.
The maximum cable length is defined in the instructions manual of the used servo
amplifier.
less than 150 pF/m
less than 120 pF/m
Electrical Installation
English - 37