SUN P7
3. SERVICE AND MAINTENANCE
All adjustment, commissioning and maintenance operations must be carried out by Qualified Personnel
in compliance with current regulations. The personnel of our sales organisation and the Local After-Sales
Technical Service are at your disposal for any further information.
FERROLI S.p.A. declines any liability for damage and/or injury caused by unqualified and unauthorised
people tampering with the unit.
3.1 Burner operation methods
Three methods are envisaged for managing burner lighting:
A. Burner management (default settings)
The request for burner lighting is activated exclusively on closing of the contact on terminals 7-8 (fig. 9).
The Clock and the set weekly programme are by-passed: the exact time does not have to be
set.
B. Burner management (With internal Clock or Contact)
The request for burner lighting can be activated by the Clock (during Automatic Heating Mode in ON
Band or in Manual On Heating Mode) or with closing of the contact on terminals 7-8 (fig. 9).
It is necessary to set the Clock and possibly modify the weekly programme default setting.
C. Burner management (With internal Clock or Contact)
The request for burner lighting is activated by the Clock (during Automatic Heating Mode in ON Band
or with Manual On Heating Mode) or if the contact on terminals 7-8 is closed (fig. 9).
It is necessary to set the Clock and possibly modify the weekly programme default setting.
The selection of A, B or C occurs from the Clock user menu.
Press the operation mode selection button "M" (detail 2 - fig. 1) for 5 seconds.
Press the Programming button "P" (detail 5 - fig. 1) twice.
Parameter no. 3, identified by the message SET 03, is displayed.
Set to 00 for mode A, 01 for mode B, or 02 for mode C with the + and - buttons (details 4 and 6 - fig. 1).
After selecting the method, it is necessary to wait 3 seconds: the data flashes and is stored. To exit
the menu, press the operation mode selection button "M" (detail 2 - fig. 1) for 5 seconds.
EN
Cod. 3540I810 - 03/2009 (Rev. 00)
45