Technical Data - Bosch LW 12/20 E Instrucciones De Servicio

Cardadar parabaterias de 12/24 v, corriente de carga de hasta 12 a
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 24
14

Technical data

Dimensions L x W x H:
320 x 335 x 207 mm
Weight:
Rated mains voltage:
Rated mains frequency:
Mains connection cable with inlet
connector for non heating appara-
tus
Rated battery voltage:
Charging leads
PVC insulation
F The charging leads must not
be changed!
Insulated charging clips:
Positive (+) = Red
Negative (–) = Black
Mains fuse:
H250 slow blow 2.5A
Thermal release in power transfor-
mer.
Ammeter
LED displays:
Yellow: Charging operation
Red:
Degree of protection (DIN 40050):
12 kg
Safety class (DIN 40530):
230 V
50 Hz
RFI suppression
EMC interference emission level:
Level I to DIN 40839
1.5 m long
Level 3 to VDE 0843, Part 2
12/24 V
Level 2 to VDE 0843, Part 4
2
6 mm
2.0 m long
Final charging voltages:
Standard batteries
Maintenance-free batteries
Charging current:
Charging characteristic:
Mains input current:
0...15 A
Power consumption:approx. 350 W
arithm.
English
Fault indication
IP 20
to VDE 0875
(IEC 801–2)
(IEC 801–4)
14.4 V or 28.8 V
13.8 V or 27.6 V
12 A
arithm.
(I) WU
max. 2.5 A
Switch on prevention in the event of
short circuit or incorrect polarity
Minimum battery voltage:
Normal charging
I
For charging
exhausted batteries
The terminal voltage is automati-
cally switched off if the charging
clips are disconnected from the bat-
tery.
Accessories
Included in the scope of delivery:
Mains connection cable 1.5 m long
Order No.: 1 684 461 106
Replacement fuse
H250 slow blow 2.5A
Order-No.: 8 784 520 047
7.5 V or 15.0 V
0.5 V
Tabla de contenido
loading

Este manual también es adecuado para:

7 780 201 032

Tabla de contenido