Technical Data

Battery Charger
Article number
Output voltage
Charging current
Allowable charging tem-
perature range
Charging time for battery
capacity, approx.
– 1.3 Ah
– 2.6 Ah
– 3.0 Ah
– 4.5 Ah
Number of battery cells
Weight according to
EPTA-Procedure 01/2003
Protection class
Please observe the article number on the type plate of
your battery charger. The trade names of individual bat-
tery chargers may vary.
Operation

Starting Operation

Observe the mains voltage! The voltage of
the power supply must correspond with the
data given on the nameplate of the battery
charger. Battery chargers marked with 230 V
can also be operated with 220 V.
Charging Procedure
The charging procedure starts as soon as the
mains plug of the battery charger is plugged into
the socket outlet and the battery 1 is inserted in-
to the charging compartment 2.
Bosch Power Tools
Due to the intelligent charging method, the
charging condition of the battery is automatical-
ly detected and the battery is charged with the
AL 3640 CV
optimum charging current, depending on bat-
Professional
tery temperature and voltage.
2 607 225 ...
This gives longer life to the battery and always
V
36
leaves it fully charged when kept in the charger
for storage.
A
4.0
Meaning of the Indication Elements
°C
0 – 45
Flashing Green Battery Charge Indicator 3
min
15 (75%)
min
45 (100%)
min
30 (75%)
During the charging procedure, the three green
min
60 (100%)
charge-control indicators 5 of the battery light
min
35 (75%)
up one after the other and briefly go out. The
min
75 (100%)
battery is fully charged when the three green in-
min
55 (75%)
dicators light up continuously. After approx.
min
90 (100%)
5 minutes after the battery has been fully
10 – 30
charged, the three green indicators go out
again.
kg
1.0
Note: The rapid-charging procedure is only pos-
sible when the battery temperature is within the
/ II
allowable charging temperature range, see sec-
tion "Technical Data".
Continuous Lighting of the Green Battery
Charge Indicator 3
Additionally, a signal tone sounds for approx.
2 seconds, which acoustically indicates that the
battery is fully charged.
Afterwards, the battery can be removed for im-
mediate use.
When the battery is not inserted, continuous
lighting of the battery charge indicator 3 indi-
cates that the mains plug is inserted in the sock-
et and that the battery charger is ready for oper-
ation.

English | 9

The rapid-charging procedure is
signalled by a flashing green bat-
tery charge indicator 3.
Continuous lighting of the green
battery charge indicator 3 indi-
cates that the battery is fully
charged.
1 609 929 X52 | (13.10.10)