F
B1
C
LED AD Current.
Indicates that the display AL shows a welding current.
During welding always shows the measured current; with
the machine at a standstill, if AG is OFF, shows the set
current.
LED AF - Globular position.
May not be selected. Active in synergic MIG process.
When lit, this signals that the pair of values chosen for
welding may give unstable arcs and splatters.
LED AG - Hold.
May not be selected. It signals that the values shown on
the displays AL and AM (normally Amperes and Volts) are
those used during last welding. Activated at the end of
each welding session.
LED AH - Voltage.
In all welding processes, it indicates that the display AM
shows the re-set welding voltage or, if in combination with
LED AG lit, the last measured voltage.
Knob AI.
The following values are set: welding current A, wire speed
(
), thickness (
), program number PRG. In the service
functions the following are selected: TRG, SP, HSA, CrA,
PrF, PoF, Acc, bb, L, Dp, PPF, Ito, Fac.
In MIG synergic processes when a value is adjusted the
other values are adjusted as well. All these values are
shown on the display AL.
12
L
M
Q
P
B
O
D
N
Fig. 1
A
Knob AN.
The following sizes are set:
In synergic MIG the arc length, in conventional MIG the
welding voltage.
Inside the service menu, according to the value set
by knob AI it selects the set value, the activation or
desactivation of the same, or an additional selection to be
made inside the fuction.
Display AL.
In all welding processes, it numerically displays the
selections made via the selection key AE and adjusted
via the knob AI.
For the welding current (LED AD) it displays the amperes.
For the wire speed (LED AC) it displays the meters per
minute.
For the thickness (LED AB) it displays the millimeters.
For (LED AA) it displays the set program number.
In the service functions the following are selected: TRG,
SP, HSA, CrA, PrF, PoF, Acc, bb, L, Dp, PPF, Ito, Fac.
For the parameters within the service functions that are
shown on the display AM, see the paragraph on service
functions.
When the machine is in the warning mode, it displays
open. When the machine is in the error mode it displays
Err.
Display AM.
Displays by the number: in synergic MIG the arc length
OPN if the lateral panel is