Operating Instructions SATAminijet 1000 K/H RP/HVLP
US
Starting to paint
■ Maintain spray distance (see Chapter 7).
■ Squeeze trigger all the way [6-2] and operate paint spray gun 90° to
the surface to be painted [6-1].
■ Provide for spray air supply and material supply.
■ Pull back on trigger [1-10] and start painting. Readjust the material flow
rate and fan pattern as needed.
Completing the painting operation
■ Move the trigger [1-10] to the start position.
■ When you are finished painting, stop the spray air and empty the
suction cup [2-9]. Read and follow the information on care and storage
(see 10).
9. Maintenance and Repair
Danger!
Risk of injury from sudden component separation or escaping
material.
If the compressed air circuit supply is not disconnected before perform-
ing maintenance work, components can detach and/or material escape
unexpectedly.
→ Disconnect the paint spray gun from the compressed air circuit before
performing any maintenance work.
Danger!
Risk of injury from sharp edges
When performing assembly work on the nozzle set, there is a risk of
injury from sharp edges.
→ Wear work gloves.
→ Always use the SATA extraction tool pointing away from your body.
The chapter below describes the maintenance and repair of the
paint spray gun. Maintenance and repair work may only be carried
out by trained experts.
■ Stop the flow of compressed air to the compressed air connection [1-7]
prior to performing any maintenance or repair work.
Replacement parts are available for repair work (see Chap. 15).
548