Trouble Shooting for Power Tool Outlet Feature
Symptom
Vac will not run
with switch in
Position 1 (on)
Vac will not start
when tool is turned
on - switch in auto
position/position
1 (on) - OK
Trouble Shooting
Symptom
Parts/accessories
missing
Vacuum cleaner
will not start
Dust discharging
from exhaust
Loss of suction
Static shock
one year limited warranty
FlEX north America warrants its Professional Power Tools for a period of one year from the date of original purchase. We will repair or replace at our option, any part or parts of the product and
accessories covered under this warranty which, after examination, proves to be defective in workmanship or material during the warranty period. For repair or replacement, return the complete
tool or accessory, transportation prepaid, to your nearest Authorized service station. Proof of purchase may be required. This warranty does not apply to o-rings and driver blades, or to repair or
replacement due to misuse, abuse, normal wear and tear or repairs attempted or made by someone other than our Authorized service stations. Any ImPlIED WARRAnTy, InCluDInG ThE
ImPlIED WARRAnTIEs oF mERChAnTAbIlITy AnD FITnEss FoR PARTICulAR PuRPosE, WIll lAsT only FoR onE (1) yEAR FRom ThE DATE oF PuRChAsE.
To obtain information on warranty performance please write to:
FLEX - North America, Inc.
2720 E. Phillips Road
Greer, sC 29650, u.s.A.
1-877-331-6103 (main line)
1-888-331-6104 (fax line)
www.FlexnorthAmerica.com
ThE FoREGoInG oblIGATIon Is FlEX noRTh AmERICAs solE lIAbIlITy unDER ThIs oR Any ImPlIED WARRAnTy AnD unDER no CIRCumsTAnCEs shAll FlEX noRTh
AmERICA bE lIAblE FoR Any InCIDEnTAl oF ConsEQuEnTIAl DAmAGEs. some states do not allow limitations on how long an implied warranty lasts or the exclusion or limitation of inci-
dental or consequential damages, so the above limitation of exclusion may not apply to you. This warranty gives you specific legal rights and you may also have other legal rights which vary from
state to state.
Possible Cause(s)
1. No power to wall outlet
2. Vacuum circuit breaker button
out or no continuity
3. Loose wire connections
4. Motor does not run
5. Defective circuit board
1. Defective power tool
2. Power tool too small (under 250 ma)
3. Power tool ok but vacuum
still will not start
4. Vac still will not start
Possible Cause(s)
1. Packed in tank
1. Defective switch
2. Defective motor
3. Vacuum circuit breaker button
out or no continuity
1. Filter not installed/not
installed properly
2. Filter damaged
3. Filter clogged or dust is too fine
4. Filter not functional
1. Loose hose connection
2. Filter clogged
3. Full tank
4. Hole in hose
1. Dry environment
2. Relative humidity of air is low
oNe YeAR WARRANtY
Corrective Action
1. Use different wall outlet
2. Push circuit breaker button in or replace
if defective
3. Assure connections are tight and connected
properly
4. Replace motor
5. Replace circuit board
1. Replace tool
2. Use larger tool
3. - Check connections
- Check tool outlet continuity
- Check rocker switch continuity
4. Replace circuit board assembly
Corrective Action
1. Check in tank
1. Replace switch
2. Replace motor
3. Push circuit breaker button in or replace
if defective
1. Properly install filter
2. Replace filter
3. Use more efficient filter
4. Clean or replace filter
1. Tighten hose connection
2. Clean or replace filter
3. Empty tank
4. Replace hose
1. Add moisture to air (if practical, use a
console or installed humidifier.)
2. This situation is temporary and does
not affect the use of the vacuum cleaner.