EMERGENCY PROCEDURE
If lift is in alarm due to misalignment, the following procedure may be attempted to reset the
alarm:
1-
Press and hold the green safety lock button.
2-
Press the up or down button to move the lift. The lift moves for 4 seconds.
NOTE: To reset the emergency state, perform the opposite manoeuvre to the manoeuvre
originally causing the emergency stop condition. For example, if the alarm was set off while
lowering the lift, try raising the lift to reset the alarm.
WARNING: Proceed with the utmost caution when performing the emergency procedure, as
it is possible for misalignment between the platforms to exceed 100 mm.
WARNING: The emergency procedure may only be performed by suitably trained and
authorised personnel.
ALARM SIGNALS:
NUMBER
FLASHES
2
3
4
5
6
8.6.2 Emergency lowering LIFT WITH MECHANICAL SAFETY
DEVICES (Lift in alarm condition - red warning light on)
If lift is in alarm due to misalignment, the following procedure may be attempted to reset the
alarm:
1-
Press and hold the green safety lock button.
2-
Press the up or down button to move the lift. The lift moves for 4 seconds.
NOTE: To reset the emergency state, perform the opposite manoeuvre to the manoeuvre
originally causing the emergency stop condition. For example, if the alarm was set off while
lowering the lift, try raising the lift to reset the alarm.
WARNING: Proceed with the utmost caution when performing the emergency procedure, as it
is possible for misalignment between the platforms to exceed 100 mm.
OF
NAME OF ALARM
ENCODER 1 ABSENT
ENCODER 2 ABSENT
ENCODERS 1 AND 2
ABSENT
LIFT NOT CALIBRATED
LIFT MISALIGNED
CAUSES
Encoder 1 is disconnected or
faulty, or the relevant cable is
damaged
Encoder 2 is disconnected or
faulty, or the relevant cable is
damaged
Encoders are disconnected, one
of the two cables is damaged.
Lift not calibrated
Difference in height between the
two platforms.