General Notions; Safety Devices; The Work Environment - TEXA ACKF01 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

4.2.5

General Notions

Before re-introducing refrigerant into the system, the system itself must be evacuated and
cleaned.
In order to be sure that the system is free of contamination before introducing the refrigerant,
all the procedures described in this instruction manual must be followed.
Clean and maintain the units regularly, especially when highly contaminated refrigerant is
used: it is extremely important that contamination from the previous operation is not
transferred to subsequent operations.
4.3

Safety Devices

ACKF01 flushing kit is equipped with an overpressure valve. This valve opens when the PS
value is reached.
Any type of tampering with the safety device mentioned above is hereby prohibited.
NEVER approach the overpressure valve when opened.Danger of pressurized
refrigerant discharge.
4.4

The Work Environment

The flushing process must be performed in open environments or in places equipped
with good ventilation (at least 4 changes of air per hour).
The Konfort A/C service stations are designed for being used at a maximum altitude of
1000 m above sea level, within a temperature range of +5 and +50°C and with a
maximum humidity of 50% at +40°C.
Operate in sufficiently lit conditions (The medium value of working illumination for
mechanical and assembly workshops (with fine workbenches) is 500-750-1000 lux).
ACKF01_GB_00
TEXA S.p.A.
76/122
Tabla de contenido
loading