DeWalt DXPW4240 Manual De Instrucciones página 11

Lavadora a presión
Ocultar thumbs Ver también para DXPW4240:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Insert saddle bolts (DD) through aligned holes and secure top
handle to handle assembly with knobs (EE). Tighten until snug.
4. Attach high pressure hose (P) to spray gun. Make sure it is secure.
5. Connect wand (E) to spray gun. Make sure connection is secure.
FIG. 3
FIG. 4
P
6. Place the nozzle holder (B) onto the panel assembly (A) and push
each nozzle holder into place.
7. Remove the five colored quick-connect nozzles from the plastic bag
and insert them into correct grommet on the nozzle holder. Nozzles
are color coded to match colored nozzles on panel assembly.
FIG. 5
B
A
NOTE: The high pressure pump was filled with oil at the factory.
Always check oil level before using (refer to Maintenance for more
information).
WARNING: Risk of bursting. Use a tire pressure gauge to check the
tires pressure before each use and while inflating tires; see the tire sidewall
for the correct tire pressure.
E
FIG. 6
11
NOTE: Air tanks, compressors and similar equipment used to inflate
tires can fill small tires similar to these very rapidly. Adjust pressure
regulator on air supply to no more than the rating of the tire pressure.
Add air in small increments and frequently use the tire gauge to
prevent over inflation.
OPERATION
Pressure Adjustments
The pressure setting is preset at the factory to achieve op ti mum
pressure and cleaning. To lower the pres sure, follow these instructions.
1. Back away from the sur face to be cleaned. The further away you
are, the less the pressure will be on the surface to be cleaned.
2. Change to the 40˚ nozzle (white). This nozzle delivers a less
powerful stream of water and a wider spray pattern. Refer to
Spray Wand Nozzles.
3. This pressure washer's high pressure
pump is equipped with an adjustable
unloader feature that allows the pressure
setting to be adjusted.
To lower the pressure, turn the
pressure control knob on the pump
counterclockwise
to
the
pressure.
To return the pump pressure to the
factory setting, turn the pressure control
knob on the pump clockwise until it
stops.
NOTICE: DO NOT try to tum pressure regulator knob past the built-in
stop or damage to the pump will result.
FIG. 7
-
+
desired
Tabla de contenido
loading

Tabla de contenido