Therefore, we do not recommend you use it to power the
following devices:
1.
Switch mode power supplies
2.
Linear power supplies
3.
Class 2 transformers
4.
Line filter capacitors
5.
Shaded pole motors
6.
Fan motors
7.
Microwave ovens
8.
Fluorescent and high intensity lamps (with a ballast)
9.
Transformerless battery chargers
Doing so may cause the device to run warmer or overheat.
3.
FASTENING THE INVERTER TO A FLAT SURFACE
For convenience, your inverter can be fastened to a flat surface,
horizontally or vertically. The area where the inverter is to
be fastened must be dry, well ventilated and away from any
combustible material or fumes.
1.
Turn off and disconnect the inverter.
2.
Place the back of the inverter with the mounting bracket
against a secure and flat surface.
3.
Attach the inverter to the flat surface using corrosion-resistant
screws.
4.
CONNECTING INVERTER CABLES
The inverter and power source must be in the OFF mode.
power supply only.
Inverter connection (Models PI-400, PI-750 and XI41B):
1.
Locate the positive and negative plastic terminals located on the
back of the inverter and remove the terminal caps completely.
2.
Install the positive (red) cable ring lug onto the positive (red)
terminal screw. Install the negative (black) cable ring lug onto
the negative (black) terminal screw. Tighten each terminal, so
that the cable cannot come loose.
This inverter uses a nonsinusoidal waveform.
Make sure you connect your inverter to a 12-volt
• 5 •