8.2  Overview of the Display Codes
Code
Parameter
X-1
Limit value H1
5PE
Power
X-2
Limit value H2
h-2
Hysteresis value h2
tbL
Ventilation time
CAL
Zero-point adjust-
ment
ctr
Control
t-1
Evacuation time
bLo
Blow off function
-E-
"External" ventila-
tion
1-t
"Internal" ventilation
E-t
"Externally time-con-
trolled" ventilation
55t
Soft Start
o-2
Signal output
o-3
Signal output
no
Normally open con-
tact
nc
Normally closed con-
tact
tyi
Signal type at the in-
put
tyo
Signal type at the
output
PnP
PNP signal type
nPn
NPN signal type
uni
Vacuum unit
-bA
Vacuum value in
mbar
-ix
Vacuum value in Hg
-PA
Vacuum value in kPa
P5i
Vacuum value in psi
dLY
Switch-off delay
5td
Default display
rot
Display rotation
Eco
ECO mode
P1n
PIN code
rE5
Reset
Cc1
Counter 1
8 / 9
Note
Deactivation value of the control function (only if ctr = on is active)
Indicates the percentage of the pump capacity in SIO mode
(only if ctr = off is active)
Activation value of "Parts control" signal output
Hysteresis of "Parts control" signal output
Ventilation time setting for internal, time-controlled blow off
(only if blo = 1-t or E-t is active)
Calibrate vacuum sensor, zero point = ambient pressure
Setting the control function
ctr = on Control function on
ctr = off Control function off, speed control via 5PE in the basic menu
Setting for the maximum permitted evacuation time in ms
Menu for configuring the blow off function
Selection of externally controlled ventilation
Selection of internally controlled ventilation (triggered internally; time can be
set)
Selection of externally controlled ventilation (triggered externally; time can be
set)
The starting current is limited to approx. 600 mA
Menu for configuring the OUT
Menu for configuring the OUT
Setting of the signal output as a normally open contact
Setting of the signal output as a normally closed contact
Menu for configuring the signal type at the input (NPN / PNP)
Menu for configuring the signal type at the output (NPN / PNP)
All input and output signals switch according to PNP (input / output on = 24 V)
All input and output signals switch according to NPN (input / output on = 0 V)
Setting the vacuum unit
The displayed values are shown in mbar
The displayed values are shown in inchHg
The displayed values are shown in kPa
The displayed values are shown in psi
Switch-off delay setting for OUT
Display is not rotated
Display is rotated by 180°
Setting ECO mode
on for display switches off
oFF for display remains on
Lo for dimmed display
Entry of the PIN code for unlocking the menu
All values are reset to the factory settings
Counter for suction cycles (suction signal input)
signal output
2
signal output
3
; Off, 10, 50 or 200 ms
2