_____________________________________________________________________
strongly; it is not necessary upon boot every time. After
discharge calibration is completed, the machine will
adjust the arc discharge current according to the
Calibration results to ensure fusion quality.
II.
1. Put the tube over one end of the fiber.
2. Use fiber stripping pliers to strip fiber coating layer, the length
of which is 30-40 mm. Use gauze dipping with alcohol or
wadding to wrap the fiber, and then clean the bare part.
3. Use a fiber cleaver to cut the fiber Bare fiber length is 16 mm
around.
4. Put the finished fiber in the Fusion Splicer. Cross-section of
fiber can not touch other things.
III.
IV.
Transfer fiber with protection sleeve from V-grooves to tube
1.
heater;
Make sure the splice point is located at the center of the
2.
protection sleeve. Put the tube at the center of the heater.
Press
3.
LED turn off when tube heating is completed.
4. Remove the tube from the heater when the heater is cool. The
whole process of Fusion Operation is completed.
V
Addenda B:
©Copyright Abacanto Digital SA.
Fiber preparation
Cover the wind protector, then the fiber fusion
automatically starts and the splicing loss is displayed.
Reinforce the fusion point
to start tube heating. The buzzer beeps and the HEAT
Repeat Step II, III, IV to continue splicing.
Manual de usuario AD300
AD Instruments
180