_____________________________________________________________________
Regular service (at least once a year) is recommended to maintain
high splicing quality.
Confirmation of splicing procedures
Refer to [Fusion procedure] (chapter 4.1.2 ).
z
Monitor suddenly turned off
The power saving function is opened by users when using a battery
z
pack.
The splicer switches to the power saving state after an
extended period of splicer inactivity. Press any key to return to the
normal state.
switches to the power saving state, refer to[Power Save]
Method to resume discharging condition parameter
z
Refer to [Referenciación o edición del modo de ]
z
Method to change error thresholds for Cleave angle, Splice loss and Fiber
angle
z Refer to [Referenciación o edición del modo de ] (chapter 4.1.2 ).
Error message can be over-ridden
Refer to [Referenciación o edición del modo de ] under [ important
settings for Fusion Option] to allow error message override.
Unable to change Arc Power and Arc Time
The settings cannot be changed in calibrate or auto modes.
Performing Arc Calibration maintains adequate arc power in these
modes.
If using the Normal or special modes, the Arc Power and Arc Time
can be changed excepting be locked by administrator.
Method to display Cleave Angle, Fiber Angle and Core / Cladding
Offsets
Refer to [Edit Fusion Operation] (section 3.2.5) to set Cleave Angle,
fiber angle, and Core / Cladding Offsets.
In the [pause 2] mode, "Core / Cladding Offsets" can be displayed .
Incorrect splice mode selected and used in AUTO mode
The AUTO mode can detect only standard SM, DS, NZ and MM
fibers. Refer to
[ Select/Editor Splice Mode]
Mismatch between Estimated splice loss and Actual splice loss
The estimated loss is a calculated loss, so it can be used for reference
only.
The optical components of the splicer may need to be cleaned.
When splicing specialty fibers, adjust [MFD-L], [MFD-R], [Core
Step] and [Core Curvature]. When splicing dissimilar fibers, adjust
also [Min. Loss] and [MFD Mismatch]. To adjust these parameters,
©Copyright Abacanto Digital SA.
To change the length of time before the splicer
Manual de usuario AD300
AD Instruments
177