STEP 4 - MAKE GAS CONNECTION
Use a new CSA International approved gas supply line.
Install a shut-off valve.
Securely tighten all gas connections.
If connected to LP, have a quali ed person make sure gas pressure
does not exceed 14" (36 cm) water column.
Examples of a quali ed person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion or re.
TYPICAL FLEXIBLE CONNECTION
CONNECT BSPP TO NPT ADAPTER TO GAS REGULATOR:
1. Apply pipe-joint compound made for use with LP gas to the male threads of
adapter
.
c
2. Insert adapter
c
using two 10" adjustable wrenches. Be sure flow arrow on regulator is pointing
up toward the range gas inlet pipe.
3. Install washer
b
range gas inlet pipe
NOTE: Washer
b
16
WARNING
Explosion Hazard
into outlet of the gas pressure regulator
in female end of adapter
via compression fitting and tighten.
a
must be used to create a leak proof seal.
, and then connect adapter
c
a
a
Gas Line from Range
b
b
Washer (provided)
c
c
Adapter (provided)
d
d
Gas Pressure Regulator
(provided)
, and then tighten
d
to
c