______________________________________________________________________ OSCILLOSCOPE KIT
4.0 -
SCOPE
•
Select SCOPE from the INSTRUMENT SELECTION page.
•
The following selections are possible:
Lab scope: use of the oscilloscope in manual mode by setting the reading
parameters as a function of the sensors and/or actuators signals to be tested.
Typical curves: if a low voltage curve is selected from the list the oscilloscope
prepares to display it by setting the voltage scale (Volt) and the time base
(time/div).
Primary: use of the oscilloscope to display the signal of the primary of the
ignition system to be tested (either Conventional or DIS).
Coil Negative Secondary (present only on SL31205/PLUS): use of the
oscilloscope to display the negative secondary signal.
Coil Positive Secondary (present only on SL31205/PLUS): use of the
oscilloscope to display the positive secondary signal.
Kilovoltmeter (present only on SL31205/PLUS): use of the capacitive
clamp to analyze polarity and intensity of the secondary signal.
Bobine test (present only on SL31205/PLUS): use of the probe as a coils
tester to determine polarity and intensity of the signal. By means of the F3 and
F5 keys, the tool sensitivity can be either decreased or increased.
OPERATING INSTRUCTIONS
43