Two SLAVE modes are available:
- Servo flash mode (SLAVE function selector set at 1)
- SLAVE flash mode (SLAVE function selector set at 2)
Servo flash mode with the mecablitz 34 CS-2 in auto
mode:
• Mount the servo flash unit on the supplied stand or on a
tripod.
• Turn on the servo flash unit with the main switch .
• Set the SLAVE function selector
unit at 1 (fig. 8). The SLAVE indicator
nently illuminated (fig. 9).
• Mount any flash unit on the camera and set the camera
to flash synch speed or a slower speed. If a mecablitz 34
CS-2 is mounted on the camera, its SLAVE function
selector
must be set at „0".
• Adjust the operating mode selector
unit to one of the three auto-working apertures. The
aperture set on the camera should be the same as the
auto-working aperture.
• Light from the servo flash unit is controlled by the built-
in sensor
depending on the setting of the operating
mode selector .
on the servo flash
will be perma-