6- MAINTENANCE

Carefully follow the recommendations and safety warnings detailed in section
1.4 of this manual.
The chlorinator has a self-cleaning system of the chlorination cell, which
reduces maintenance considerably. In any event, it is advisable to clean the cell
and check the chlorine (Redox), free chlorine or pH probe if available.
Bear in mind that both the electrolysis cell and the REDOX probe wear out
through use. If after cleaning, the equipment does not work properly, the probe
or cell should be replaced. Your distributor will be able to advise you on the
need to change these elements.

6.1- Cleaning the electrolysis cell

The electrolysis cell should be cleaned in the following circumstances:
-
If the low level of salt indicator comes on and the concentration is
correct.
-
If the overload indicator comes on and the level of salt is correct.
-
If lime scale is observed on the surfaces of the electrodes. In this case,
the equipment can also be adjusted so that the frequency between each
automatic cleaning operation is less. This frequency will depend on the
hardness of water in your area.
Submerge the cell in a hydrochloric acid solution or use a commercial product
to clean electrolysis cells (CELLCLEAN). Do not use sharp objects that could
damage the titanium coating of the electrodes.