en
|
Description
Indicator
Segments light up in green.
Segments light up in green.
Segments blink yellow or red. Fault (see
1) The residual capacity of the gas filter or the gas filter components of
the combination filter cannot be indicated.
Warning devices
The blower unit displays malfunctions with segments flashing
red or yellow on the control panel. The blower unit will also
trigger an acoustic and vibration alarm.
Depending on the thickness and material of the clothing,
the vibration alarm might not be perceived.
2.2.2 Filter and facepieces
Filter and facepieces are described in separate Instructions
for Use.
The facepiece half/full mask types and hood/helmet/protective
visor have varying flow ranges. The blower unit automatically
detects the respiration connection type and automatically
selects the appropriate flow range.
2.2.3 Breathing hoses
The following breathing hoses are available:
– standard hose
– flexible hose for increased comfort
Both breathing hoses are available for each of the following
facepiece types:
– plug-in connector (hood)
– bayonet-type connector (helmet and protective visor)
– round-thread connector (half/full face mask)
2.2.4 Carrying systems
Illustration on the fold-out page (Figure E)
1 Connection plate
2 Webbing
3 Clips on ends of the belt
4 Buckle
The following carrying systems are available:
– Standard belt
The standard belt consists of a textile webbing and press
studs to attach comfortable padding.
– Decontaminable belt
18
Meaning
Residual particle filter capac-
1)
ity
depending on number of
displayed segments:
> 75 % (4 segments)
> 50 % (3 segments)
> 25 % (2 segments)
< 25 % (1 segment)
Flow rate intensity depending
on number of displayed seg-
ments:
high flow rate (3 segments)
medium flow rate (2 seg-
ments)
low flow rate (1 segment)
chapter 4 Troubleshooting)
The decontaminable belt has a smooth plastic webbing
and is particularly recommended for decontamination.
– Welding belt
For the welding belt, the webbing is made of leather. The
welding belt is intended for use when welding.
2.2.5 Rechargeable batteries
Illustration on the fold-out page (figure F)
1 Battery lock button
2 Battery status indicator
3 Button to display battery capacity
4 Name plate
The rechargeable lithium-ion batteries are specially designed
for use with the powered air purifying respirator. A long-life
rechargeable battery is also available in addition to the
standard rechargeable battery.
Rechargeable batteries for the different X-plore 8500 and
X-plore 8700 device types cannot be interchanged.
The battery status indicator shows the battery capacity while
you charge the unit with the standard charger or when you
push the button. The segments of the battery status indicator
are flashing while you charge the unit.
The battery status indicator is identical to the one on the
blower unit control panel (see chapter 2.2.1 Blower unit).
The rechargeable batteries reach their full capacity after
5 charge and discharge cycles. The standard charging time
takes approx. 3 hours.
In cases where the rechargeable battery has been completely
drained, charging may take up to 4 hours. During this time the
battery status indicator is not supported.
To prevent damage to or explosion of the rechargeable
battery, charging is limited to a temperature range of 0 to
50 °C. If this temperature range is exited, the charging
process will stop automatically and continue once within the
temperature range again.
2.2.6 Standard battery charger
Illustration on the fold-out page (Figure G)
1 Status LED
2 Power supply unit
3 Battery compartment
Explanation of the status LED
Indicator
Meaning
Rechargeable battery is inserted and
fully charged (standby mode)
Status LED is green.
Rechargeable battery is inserted and
being charged.
Status LED is flash-
ing green.
Temporary disruption of charging
(e.g. from excessively high tempera-
Status LED is flash-
ture)
ing yellow.
Instructions for use
|