reserve lifeline deployment, pull lifeline out of the SRL until it
stops. If the red band indicator is visible, the reserve lifeline has
been deployed. If the reserve lifeline has not been deployed,
that portion is acceptable and the inspection can continue.
◊ SB Series Models: These SRLs do not have a reserve lifeline
feature.
◊ UltraLok Web Lifeline Models: Inspect the reserve lifeline
payout. If a fall has been arrested with most of the lifeline out,
the reserve lifeline may have been deployed. Pull the lifeline out
of the SRL until it stops. If the reserve lifeline label (F) is vis-
ible, as shown in Figure 7, the reserve lifeline is deployed and
the unit must be serviced by an authorized service center before
reuse. If the reserve lifeline has not been deployed, continue
with inspection.
◊ Synthetic Rope Lifeline Models: Inspect the reserve lifeline
payout. If a fall has been arrested, it is possible the reserve
lifeline has been deployed. To inspect for reserve lifeline deploy-
ment, pull lifeline out of the SRL until it stops. If the reserve
lifeline warning label (A) is visible, the reserve lifeline has been
deployed. See Figure 37. If the reserve lifeline has not been
deployed (the reserve lifeline label is not visible) that portion is
acceptable and the inspection can continue.
IMPORTANT: If indicators are visible, the unit must be serviced by
an authorized service center before reuse.
Step 10. Inspect each system component or subsystem according
to manufacturer's instructions.
•
INSPECTION STEPS FOR RETRIEVAL COMPONENTS: (MODELS
3400101, 3400102, 3400301, 3400302, 3400501, 3400502) See
Figure 2
Step 11. Inspect retrieval arm (A) for distortion or other damage.
Retrieval handle (B) should engage into retrieval arm
with ease and push button should work freely.
Step 12. Shift knob (F) should rotate freely when engaging/
disengaging. Pull ring (D) on shift knob should spring
back when released.
Step 13. Inspect retrieval mode for operation. To test, raise and
lower a test weight (sand bag) of between 34 kg and
141 kg. Retrieval operation should be smooth and even.
When the retrieval handle (B) is released, the weight
should not move and retrieval handle should stay in
position (no movement). A "clicking" sound should be
evident when raising load.
31