FL8I Intelligent programmer - 220V / 115V
Generalities
The new Lama programmer, FL8i, with intelligent technology pre-
sents a series of features which make it unique in the market.
When turning on the programmer, it starts a
sequence which verifies all the filtering stations and in case of fin-
ding any problems it is notified as an alarm system.
Once the checking is done, the programmer starts the filtering
cycle. When the pressure difference P+ and P-, taken by the FL8i
sensors exceeds the data previously stored in the memory, which
may be modified by the user, the FL8i goes on to cleaning the filter,
which has several phases controlled by a timer (also able to be
modified by the user).
If the pressure is not enough to carry out the cleaning or filtering
operations, the intelligent programmer can regulate the water flow by
setting off the stabilising valve.
The parameters which control the programmer are delivered
with a standard programme for the filter they are made for,
although they may be shaped by the user in order to adapt the fil-
tering and cleaning of the specific conditions of each installation.
The programmer is shaped at the factory with a set of Standard
parameters.
The following User's Guide deals with the modifiable options by
the final user, for such cases where a change of said parameters are
EN
required.
There are other options in the programmer, which can only be
modified by the expert team of Lama for certain cases.
Never try to modify the parameters which are not shown in this
guide, as serious damage could be done and / or cancel the gua-
rantee of the programmer. The colour flashing lights tell us about
the state of the filters, Green light: normal, Yellow light: Precaution
(revision required), Red + Acoustic sign: Danger (user's aid is required)
Even though the programmer alarm is set off, it continues working.
Language: standard in Spanish. Also in English and french by changing the language chip.
Technical features
• Self checking.
• Inlet tension: 115V / 230V.
• No. Of outlets: From 1 to 8.
• Outlet tension at solenoid: 24V.
• Watertight security chamber.
• Wide screen multifunction
• Languages selection available according to chip: Consult

Electrical connection

Mains
voltage
230V
Mains
voltage
115V
28
Out to the
transformer
Common out
solenoid
Out to the
thransformer
Serious error (red)
self checking
• Selection of Measures: BAR / PSI.
• Pressure rank between 0.1 and 10 Kg/cm².
• Automatic rearmament fuse.
• Cleaning indicator of the auxiliary filter
• Over pressures and water hammer protector.
• Automatic control of cleaning and service pressures
Out Master
valve
Filtration Stations
solenoid
Multifuntion (Yellow)
Acoustical Alarm
Sensor intake
inlet pressure P P + +
Outlet at solenoid
P P + + : : Inlet pressure in the filtration headers.
p p -: : Outlet pressure in the filtration headers.
P P D D : : Differential pressure, standar 0,5Kg/cm² and modifiable.
M M e e d d i i u u m m I I n n t t e e r r v v a a l l : : Is the time measure in the last 99 cleaning.
L L a a s s t t i i n n t t e e r r v v a a l l : : Is the time measure in the last 10 cleaning.
C C T T : : Total counter of cleaning (isn't able to be modified by user).
C C P P : : Partial counter of cleaning (is able to be modified by user).
0 0 0 0 : : 0 0 0 0 : : Time since the last cleaning
Operation (green)
Auxiliar intake of filter P P f f
Sensors intake
outlet pressure p p -