stEP tHrEE:
set the Automatic Flush Cycle timing
1
2
3
4
5
6
On
Off
For soft water without
a softener or filter.
1
2
3
4
5
6
On
Off
For hard water without
a softener or filter.
M29614
TrueSTEAM Humidification System 69-2285EFS—05
4
5
6
M29610
4
5
6
M29611
4
5
6
M29612
4
5
6
M29613
1
2
3
4
5
6
On
Off
For water that is filtered through
the Honeywell RO Filter System.
1
2
3
4
5
6
On
Off
For water that is put through
a softener before
entering TrueSTEAM.
DIPs 3, 4, and 5 are used for humidifying.
DIP 3: Used to enable wireless operation.
•
If DOWN (default), wireless terminal is disabled.
•
If UP, wireless terminal is enabled.
DIP 4: Used to configure power monitoring.
•
If DOWN (default), TrueSTEAM looks for R input
before allowing humidity.
•
If UP, TrueSTEAM does not look for R Input before
allowing humidity. Power is still allowed to pass
through if R is wired. See "Make Power Monitoring
Decision" on page 14.
DIP 5: Used to configure back-up air
proving (optional).
•
If DOWN (default), TrueSTEAM does not look for air
movement through an air proving device.
•
If UP, TrueSTEAM looks for C connection before
allowing humidity. Wire an air proving device
between TrueSTEAM C and System C. See "Make
Add-On Air Proving Decision" on page 18.
Note: Setting DIP 5 up requires DIP 4 to be down. If DIP 4 is up, DIP 5
position will not be used.
DIP 6: Not used at this time.
•
Use DIP 1 and DIP 2 to configure how often
TrueSTEAM will automatically flush the tank.
Timing for the automatic flush is based on hours of
active heating element time.
•
The home's water hardness determines how often
automatic flushing should be performed.
•
The automatic flush timing can be changed any
time after installation by setting the DIP 1 and
DIP 2 positions, as shown at left. See "Automatic
Cleaning Cycle" on page 24 for a description of
the automatic flushing process.