MELSEC iQ-R Series
Programmable Logic Controllers
Installation Manual for Base Units,
Power Supplies and CPU Modules
Art. no.: 301714 ENG, Version B, 13012020
Safety Precautions
For use by qualified staff only
The instructions in this manual are written for qualified electrical technicians
who are already familiar with automation technology safety standards. System
configuration and layout, installation, setup, servicing and testing of the
equipment may only be performed by qualified electrical technicians. Any
modifications to the hardware and/or software of our products not specifically
described in this manual may only be performed by authorised Mitsubishi
Electric staff.
Proper product use
The programmable logic controllers (PLCs) of the MELSEC iQ-R series are only
intended for the applications described in this installation manual and/or the
other manuals referenced below. All operating parameters and settings spec-
ified in this manual must be observed. The products described have all been
designed, manufactured, tested and documented in strict compliance with
the relevant safety standards. Unauthorised modification of the hardware or
software or failure to observe the warnings in this manual and on the products
may result in serious injury to personnel and/or damage to property. Only
peripherals and expansion equipment specifically recommended and
approved by Mitsubishi Electric may be used with the programmable logic
controllers of the MELSEC iQ-R series. All and any other uses shall be deemed
to be improper.
Safety regulations
All safety and accident prevention regulations relevant to your application
must be observed in your system configuration and layout and for installation,
setup, servicing and testing of these products.
This manual includes warnings to help you use the products properly and
safely. These warnings are identified as follows:
DANGER:
P
User injury hazard.
Failure to observe these safety warnings can result in health
and injury hazards for the user.
WARNING:
E
Equipment damage hazard.
Failure to observe these safety warnings can result in serious
damage to the equipment or other property.
Additional information
You can find more information on these products in the following manuals
P MELSEC iQ-R CPU Module User's Manual (Startup)
P MELSEC iQ-R CPU Module User's Manual (Application)
P MELSEC iQ-R Module Configuration Manual
P MELSEC iQ-R Ethernet/CC-Link IE User's Manual (Startup)
You can download these manuals from our website free of charge
(https://eu3a.mitsubishielectric.com).
If you have any questions about installing, programming and operating
MELSEC iQ-R series controllers, please don't hesitate to contact your local sales
office or distributor.
System Configuration
The PLCs of the MELSEC iQ-R series are modular controllers. The CPUs are
installed on base units (sometimes referred to as racks) that can also accom-
modate a power supply and up to twelve modules.
You can expand the system by connecting extension base units to the main
base unit with a bus cable.
B
B
B
O
Main base unit
A B
C C
U
T
C
C
C
D
Extension base unit
A C
C C C
C C C C
O
I
U
N
(extension 1)
T
D
Extension base unit
O
A C
C C C
C
I
U
(extension 2)
N
T
No.
Description
Slot for power supply unit
A
Slots for CPU modules
You can install up to four CPU modules in a single MELSEC iQ-R
B
series PLC system.
Slots for I/O modules and special function modules.
C
Extension cable
D
E
WARNING
The total length of all extension cables in a PLC system must not exceed
20 m. (13.2 m when a MELSEC System-Q series module is used in the system.)
Max. extension
CPU module
Max. installable modules
base units
RnCPU
a
64
RnENCPU
b
7
63
64
RnPCPU
c
a
R00CPU, R01CPU, R02CPU, R04CPU, R08CPU, R16CPU, R32CPU, R120CPU
b
R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, R120ENCPU
c
R08PCPU, R16PCPU, R32PCPU, R120PCPU
General Operating Conditions
Condition
Specifications
0–55 °C
a
Operation
Ambient
0–60 °C
b
temperature
Storage
-25–75 °C
Relative humidity (operation)
5–95 % (non-condensing)
No aggressive or flammable gases,
Environment
no excessive dust
a
When an extended temperature range base unit is not used.
b
When an extended temperature range base unit is used.
Please refer to the MELSEC iQ-R Module Configuration Manual for more details
on the operating and environment conditions for the controllers.
Base Units
Parts and controls
Main base unit
H
R38B
A
POWER
CPU
I / O 0
I / O 1
OUT
B
C
4
5
6
Extension base unit
H
R68B
A
POWER
I / O 0
I / O 1
IN
OUT
B
9
C
4
6
RQ extension base unit (for MELSEC System Q modules)
H
RQ612B
A
OUT
I / O 0
I / O 1
POWER
IN
J
9
C
4
6
No.
Description
Extension connector cover
A
A protective cover for the extension cable connector
Extension cable connector (OUT)
B
Connector for connecting to an extension base unit. A MELSEC iQ-R
series extension cable is connected here.
Production information marking
C
Shows the production information (16 digits) of the base unit.
D
Slot for power supply unit
Slot for CPU module
E
I/O module slots
F
Guides for mounting the modules to the base unit.
G
Threaded holes for mounting modules with M3 x 12 screws.
H
Extension cable connector (IN)
Connector for incoming extension cable (from main base unit or
I
another extension base unit)
Extension cable connector (OUT)
Connector for connecting to a MELSEC System Q series base unit (lower
J
level). A MELSEC System Q series extension cable is connected here.
The number of slots available for I/O modules and special function modules is
indicated by the second and (if present) third numeric digits in the model
designation. For example, the R38B has 8 slots and the R312B has 12 slots.
Dimensions
R38B
POWER
CPU
I / O 0
I / O 1
I / O 2
OUT
I / O 2
I / O 3
X
Base unit
X [mm]
Base unit
X [mm]
R35B
245
R65B
245
R38B
328
R68B
328
R310B-HT
439
R610B-HT
439
R312B
439
R612B
439
G
I / O 2
I /
G
I / O 2
I / O 3
G
I / O 3
I / O 4
I / O 5
I / O 6
I / O 7
Base unit
X [mm]
RQ65B
245
RQ68B
328
RQ612B
439
Tabla de contenido
loading

Resumen de contenidos para Mitsubishi Electric MELSEC iQ-R Serie

  • Página 25: Controladores Lógicos Programables

    I / O 3 POWER Número máximo de se permite el empleo de los dispositivos adicionales o de ampliación recomen- dados por MITSUBISHI ELECTRIC. Todo empleo o aplicación distinto o más unidades base de Número de módulos Módulo CPU amplio del indicado se considerará como no reglamentario.
  • Página 26 Unidades de alimentación Módulos CPU R01CPU, R02CPU N° Descripción Con las cubiertas delanteras abiertas Elementos de mando Compartimento para la pila FX3U-32BL Elementos de mando R00CPU Interruptor de modos de funcionamiento P RUN: Se está procesando un programa PLC. Con las cubiertas delanteras abiertas P STOP: No se está...
  • Página 27 R04CPU, R08CPU, R12CPU, R32CPU, R120CPU, R08PCPU, R12PCPU, R04ENCPU, R08ENCPU, R16ENCPU, R32ENCPU, R120ENCPU N° Descripción N° Descripción R32PCPU, R120PCPU Con las cubiertas delanteras abiertas Indicación de la velocidad de transmisión Indicación de la velocidad de transmisión Con las cubiertas delanteras abiertas por Ethernet y el estado de conexión.
  • Página 28: Dimensiones

    Instalación Dimensiones Montaje de las unidades base R04CPU, R08CPU, R12CPU, R32CPU, R120CPU, R08PCPU, R12PCPU, R32PCPU, R120PCPU R00CPU, R01CPU, R02CPU Las unidades base del serie iQ-R de MELSEC pueden montarse tanto directa- mente sobre una base plana (p.ej. la pared trasera de un armario de distribu- PELIGRO ción), como sobre un carril DIN.
  • Página 29 Montaje en carriles DIN Q6DIN1, Q6DIN2 Conexión del cable de extensión Instalación de los módulos en la unidad base Hay adaptadores disponibles para el montaje de las unidades principal y de Cara posterior de la unidad base extensión sobre un carril DIN con 35 mm de anchura. Para garantizar una ins- ATENCIÓN ATENCIÓN talación segura, los tornillos para la fijación del carril dentro del armario de dis-...
  • Página 30: Conexión

    Dado que el borne LG no es libre de potencial, además existe el peligro de una descarga eléctrica al tocar ele- mentos o superficies conductores. Mitsubishi Electric Europe B.V. /// FA - European Business Group /// Germany /// Tel.: +49(0)2102-4860 /// Fax: +49(0)2102-4861120 /// https://eu3a.mitsubishielectric.com...